Publication: Effect of averaging of high-resolution cardiac signals in medical diagnostics using simson's method
| dc.contributor.author | Wenjia, G. | |
| dc.contributor.author | Ivanov, M. L. | |
| dc.contributor.author | Turushev, N. V. | |
| dc.contributor.author | Avdeeva, D. K. | |
| dc.contributor.author | Yuzhakov, M. M. | |
| dc.contributor.author | Иванов (Ivanov, M. L.), Максим Леонидович | |
| dc.contributor.other | Кафедра «Электроника и автоматика физических установок» (ЭиАФУ) | |
| dc.date.accessioned | 2026-10-09T05:39:44Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Simson’s method employed in cardiological diagnostics detects the presence or absence of late ventricular potentials to indicate cardiac pathologies. It has been a long time since the development of Simson’s method, but it is still used in clinics and is often mentioned in studies related to high-resolution ECGs and averaging of ECG signals. An optimal algorithm of high-resolution ECG averaging was chosen and implemented in this study. Efficiency of Simson’s method was assessed on the cardiac signal recorded using a modern hardware and software complex. The result of the study showed no relationship between late ventricular potentials and localized micropotentials on the ST interval in individual cardiac pulses. | |
| dc.format.extent | pp. 12028 [5 p.] | |
| dc.identifier.citation | Effect of averaging of high-resolution cardiac signals in medical diagnostics using simson's method / G. Wenjia, M. L. Ivanov, N. V. Turushev [et al.] // Journal of Physics: Conference Series, V International Conference on Innovations in Non-Destructive Testing SibTest 26–28 June 2019, Yekaterinburg, Russia. – Yekaterinburg, 2019. – Vol. 1327. – pp. 12028 [5 p.], – DOI 10.1088/1742-6596/1327/1/012028, EDN: YOTITC | |
| dc.identifier.doi | 10.1088/1742-6596/1327/1/012028 | |
| dc.identifier.other | EDN: YOTITC | |
| dc.identifier.uri | https://openrepository.sti.mephi.ru/handle/123456789/4004 | |
| dc.identifier.uri | https://www.doi.org/10.1088/1742-6596/1327/1/012028 | |
| dc.identifier.uri | https://elibrary.ru/item.asp?id=41709990 | |
| dc.identifier.uri | https://elibrary.ru/yotitc | |
| dc.identifier.uri | https://iopscience.iop.org/article/10.1088/1742-6596/1327/1/012028/meta | |
| dc.language.iso | en | |
| dc.relation.ispartof | Journal of Physics: Conference Series, 6–28 June 2019, Yekaterinburg, Russia | |
| dc.title | Effect of averaging of high-resolution cardiac signals in medical diagnostics using simson's method | |
| dc.type | Conference Paper | |
| dspace.entity.type | Publication | |
| oaire.citation.volume | Vol. 1327 | |
| relation.isAuthorOfPublication | 9bfe120f-1715-4214-b24a-e3d254f7e272 | |
| relation.isAuthorOfPublication.latestForDiscovery | 9bfe120f-1715-4214-b24a-e3d254f7e272 | |
| relation.isOrgUnitOfPublication | b8b3dc05-ada8-41b0-826e-bf72b0b7e8c9 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | b8b3dc05-ada8-41b0-826e-bf72b0b7e8c9 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Effect of averaging of high-resolution cardiac signals in medical diagnostics using simson's method.pdf
- Size:
- 1.39 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 3.58 KB
- Format:
- Item-specific license agreed to upon submission
- Description: